Eliwell CAPE+ Cold Room Trapped Person Alarm

Eliwell CAPE+ Cold Room Trapped Person Alarm

£247.00£247.00 Excl. VATInc. VAT

SKU: ECAPECTPA

Product Overview

  • Illuminated emergency push button
  • Audible and flashing visual alerts
  • Sealed lead battery backup during power failures
  • Optional open-door alarm functionality
  • Optional refrigerant gas leak monitoring via an Eliwell LKD detector
  • 230V AC mains operation

Description

Description

Eliwell CAPE+ Cold Room Trapped Person Alarm

The Eliwell CAPE+ cold room trapped person alarm provides an essential emergency warning system for commercial cold rooms, walk-in freezers and refrigerated storage facilities.

The system combines an illuminated emergency push button inside the chamber with an external alarm box. If someone becomes trapped inside, they can activate the button to trigger an audible alarm and flashing warning light. Furthermore, the CAPE+ supports additional monitoring through optional door contacts and compatible refrigerant gas detectors.

Reliable Emergency Protection for Cold Rooms

The CAPE+ helps personnel raise the alarm quickly when they cannot leave a cold room or freezer.

Its illuminated emergency button helps users locate the control inside the chamber. Once someone presses the button, the external unit activates audible and visual warnings to attract attention. In addition, a sealed lead battery maintains emergency alarm operation during mains power interruptions.

Key Features and Benefits

Emergency Safety Features

  • Trapped person alarm: Activates audible and flashing visual warnings during emergencies.
  • Illuminated emergency button: Helps personnel locate the emergency control inside the cold room.
  • Battery backup: Maintains alarm operation during mains power interruptions.
  • Multiple emergency controls: Supports up to six emergency contacts.

Monitoring and Configuration

  • Door-open monitoring: Supports a compatible door contact and adjustable alarm delay.
  • Gas leak monitoring: Connects to an optional Eliwell LKD detector.
  • Flexible configuration: Allows installers to select normally open or normally closed contact operation.

Additional Door and Refrigerant Monitoring

Alongside its primary emergency function, the Eliwell CAPE+ can monitor cold room doors and refrigerant gas detection systems. For door monitoring, installers can configure a delay of up
to 62 minutes before the unit activates its warning. Additionally, a compatible Eliwell LKD detector can trigger the alarm when it identifies a refrigerant gas leak.

These optional functions combine several cold room monitoring capabilities within one alarm system.

Suitable Applications

The Eliwell CAPE+ supports emergency alarm arrangements in:

  • Commercial cold rooms
  • Walk-in freezer rooms
  • Refrigerated warehouses
  • Food processing facilities
  • Industrial refrigeration installations
  • Temperature-controlled storage areas

Order Your Eliwell CAPE+ from Coldroom Solution

Choose the Eliwell CAPE+ cold room trapped person alarm for emergency signalling in your commercial refrigeration installation.

Explore the Technical Details tab for electrical specifications, operating conditions and compatible accessories.

For further information or assistance with product selection, contact the Coldroom Solution team.

Technical Details

Explore the specifications, alarm functions and operating requirements of the Eliwell CAPE+.

General Information
Manufacturer Eliwell
Model CAPE+
Product Type Cold Room Trapped Person Alarm
Alarm Functions
Emergency Activation Illuminated Push Button
Alarm Indication Audible Siren & Flashing Light
Emergency Contacts Up to 6
Door-Open Alarm Optional Door Contact
Door Alarm Delay 0–62 Minutes, 2-Minute Steps
Gas Leak Monitoring Optional Eliwell LKD Detector
Low Battery Alert Flashing Visual Warning
Electrical Specifications
Power Supply 230V AC ±20%, 50/60Hz
Battery Backup Sealed Lead Battery
Battery Alarm Autonomy 18 Hours*
Relay Output 1 NO + 1 NC
Buzzer Output 12V, 3W
Operating Conditions
Control Box Protection IP44**
Operating Temperature -20°C to +60°C
Humidity 0–95% RH, Non-Condensing
Emergency Button Size 74 × 68 × 62mm
Maintenance & Accessories
Battery Inspection Annually
Battery Replacement Every 3 Years
Optional Accessories LKD100/200 Detector, Door Contact, Spare Battery Kit

* The manufacturer’s 18-hour autonomy figure assumes a charged battery and six emergency push buttons.

** The supplied technical document specifies IP44. Confirm the exact product revision before publication.

Optional accessories may require separate purchase. Consult the manufacturer’s instructions before installation.

Downloads

Product Downloads

View or download the product’s technical and installation manual.

CAPE+ – Technical Manual